Product Name
flexwatt heat tape
self regulating cable
25W/30w/45w per meter at 10 deg c
deicing heating cable /roof gutter snow melting / walk in cold door frame heating wire
Product Properties
Brand: yiteng
Model: DXW-J-25-220
DXW-P-25-220
DXW-P/F-35-220
Certification: CE ISO ISO9001 ISO14001 CCC
Origin: hebei
Trading Information
Minimum order quantity: MOQ 100meters
Price: FOB tianjin USD 1.0-3.0 per meter
Payment method: T/T L/C DA DP Western Union
Supply Ability: 10000 meters per week
Delivery date: 10-15 days after payment
Conventional packaging: 100meter per roll then 3-4 rolls in a paper carton
Product Description
flexwatt heat tape FEATURES
Model: DXW-J-25-220 DXW-P-25-220 DXW-P/F-35-220
Parameters:
1.standard color: Red
2.max holding temperature: 65±5℃ or 105 ±5℃ max surface temp 70±5℃ or 105 ±5℃ max bearing temp 105℃
3.laying ambient temp: min -40℃
4.heat stability: after cycling 300 times between10℃-99℃,heating value maintain above 90%
5.bending radius: 25.4 mm at 20℃,35.0 mm at -30℃
6.Insulation resistance: min 1200 MΩ, cable length 100 m
7.ambient temp 75℃. test with 2500 V DC megger with duration 1 minute, insulation resistance between wires and shields is 1200 MΩ
ADVANTAGES
1.Temperature evenness, not overheat, safety and reliable
2.Can be cut or spread within certain length at random
3.Multiple overlapping is allowed
4.Output power can be auto regulated along with heated system
5.No pollution, energy saving, and easy installation
6.Suitable for antifreezing of instrument box
7.Suitable for complex pipeline heat tracing
APPLICATIONS heat tracing / defrost / deicing
heating solutions for all industries such as industrial heat tracing, floor heating, snow melting and roof or gutter deicing, pipe frost protection, etc.
flexwatt heat tape TYPES AND SPECIFICATIONS max 65 deg c
Type |
Model | Structure |
Working voltage V |
Max. length (m) with single power 220V |
||
Basic type J(W/M) |
Shielded type P(W/M) |
anti- corrosive type P F (W/M) |
||||
self regulating | low temp | J(10) | P(25) | P/F(30) | 24/36/110/ 220/380V |
≤100 |
J(15) | P(30) | P/F(35) | ≤100 | |||
J(20) | P(35) | P/F(40) | ≤100 |
Explosion Mark: EXe II T6
Appr Outer Diameter: 14mm * 6 mm
flexwatt heat tape TYPES AND SPECIFICATIONS MAX 105 DEG C
Type | Model | Structure | Working voltage V | Max. length (m) with single power 220V | ||
Basic type J(W/M) | Shielded type P(W/M) | anti- corrosive type P F
(W/M) |
||||
self regulating | Mid temp | J(25) | P(40) | P/F(45) | 24/36/110/
220/380V |
≤100 |
J(35) | P(45) | P/F(55) | ≤100 | |||
J(40) | P(55) | P/F(65) | ≤100 |
Mid temp heat tracing cable is widely used for pipeline civil solar heater tape, geothermal heater tape ,petroleum,chemical, steel, and electric power industrial enterprises, as well as warming, anti-freezing of storage tanks. The cable is suitable for general area and corrosive area
flexwatt heat tape Structure:
1 buss wire :tinned copper7/0.23/0.3/0.43/0.5mm,19/0.23/0.3mm
2 NM heating element:conductive plastic
3 inner sheath:Polyolefin insulation
4 braided shield: tinned copper wire or magal
5 outer sheath: modified polyolefin,falme retardant polyolefin,fluoride polyolefin,perfluorinated material
J means: basic 1+2+3
P means: protection 1+2+3+4
P/F means: anti-corrosive 1+2+3+4+5
Voltages Available: 24V 36V 110V 220V 380V
Wattage Available: 10W/M ,15W/M ,20W/M ,25W/M ,30W/M ,35W/M ,40W/M, 45W/M